Joint Press Release with the Consumer Affairs Agency Recall of Dehumidifiers Imported by IRIS OHYAMA INC. (Product Inspection and Repair)

Product accidents occurred in dehumidifiers imported by IRIS OHYAMA INC., igniting the products and their surroundings.

The Ministry of Economy, Trade and Industry (METI) was informed of these accidents as a serious product accident and announced them on August 9, 2016, in accordance with Article 35 (1) of the Consumer Product Safety Act, which relates to an accident of unclear origin in a product other than a gas or oil appliance.

To prevent further accidents, on August 24, 2016, the company made an official announcement on its website that it was starting product inspections and repairs of the product models in question.

METI encourages customers who have purchased the products subject to the recall to utilize the inspection and repair service offered by the importer in order to prevent any further accidents.

1. Nature of the accident and recurrence-prevention measures

1) Nature of the accident

Product accidents occurred in dehumidifiers imported by IRIS OHYAMA INC., igniting the products and their surroundings.

Two serious accident reports subject to Article 35 (1) of the Act have been submitted (Control Nos.: A201500597, A201600240).

The cause of the accidents is under investigation, but it is thought that defective control switches, which were installed to stop the power supply if overturned, anomalously overheated, causing the products to emit smoke and ignite.

In addition, another product accident was reported to the National Institute of Technology and Evaluation (NITE), but it is not covered by Article 35 (1) of the Act.

No injuries occurred as a result of these accidents.

2) Recurrence-prevention measures

To prevent further accidents, on August 24, 2016, IRIS OHYAMA INC. will make an official announcement on its website, send direct mail to known consumers and post notices to customers in relevant shops and will start inspections and repairs of the products to be recalled free of charge.

2. Products to be recalled: outline of the products, appearance, and how to check the data

1) Product name: Dehumidifier

Those sold by IRIS OHYAMA INC. between January 2013 and July 2016

Name of products to be recalled, model number, import/sales period and number of units
Product name Model number Serial numbers Sales period Sales period
Dehumidifier (desiccant type) EJD-70N 121200001-160299999 January 2013 to July 2016 26,551

2) Product Verfication

Appearance

Verification method

[i] Description of the products in question

Check the model number and serial number on the sticker on the back of the product
Products with the model numbers above and any with the serial numbers from 121200001 to 160299999 are to be recalled.

[ii] Products not to be recalled

Products with a serial number from 121200001 to 160299999 and an “Inspected” sticker adjacent to the serial number, which is proof that the products have already been inspected and repaired

3. Actions by the company

The company will provide inspections and repairs of the products to be recalled free of charge.

4. Notice by the company

Website: Wednesday, August 24, 2016
Sending direct mail to known customers: August 24, 2016, onward
Posting notices in shops: Wednesday, August 24, 2016, onward

5. Alert to consumers

Anyone who has purchased any of the above products should contact the company as indicated below.
(contact counter will open on August 24, 2016.)

6. Contact

Contact counter
IRIS OHYAMA INC. contact counter exclusively for the recall of dehumidifier EJD-70N
Telephone (toll free): 0800-222-8989 (cell-phone and PHS calls are also accepted.)
Service hours
Mondays to Fridays: 9:00–17:00
Saturdays, Sundays and holidays: 9:00–12:00/13:00–17:00
Note: Not operating during year-end and New-Year, summer holidays, and business holidays
Contact counter
http://www.irisohyama.co.jp/safetyinfo/ejd-70n.htmlexternal link

Release date

August 24, 2016

Division in Charge

Product Accident Information and Analysis Office, Product Safety Division, Commerce, Distribution and Industrial Safety Policy Group